首頁 > 產品一覽 > 光學測試設備 > Material Analyzer > Laser Induced Breakdown Spectroscopy
 

Laser Induced Breakdown Spectroscopy

PORTA-LIBS-2000 can be useful for a variety of applications. Here’s just a few:
● Industrial materials analysis
● Prospecting & Mining
● Environmental monitoring
● Homeland security measures
● Military chemical and biological agents
● Forensics analysis
● Pharmaceutical R&D
● Engine Oil analysis
● Gemology and Counterfeit detection
  • 型號
  • 產品概述
  • 庫存
  • 詢價數量
  • 詢價車
UV2

Wavelength Range (nm) : 200-400

  •  Wavelength Range in nm  200-400
     Grating g/mm  2400
     Slit-14 nm res.  0.20

     

加入
VIS4

Wavelength Range (nm) : 400-600

  •  Wavelength Range in nm  400-600
     Grating g/mm  2400
     Slit-14 nm res.  0.20

     

加入
VIS4b

Wavelength Range (nm) : 600-800

  •  Wavelength Range in nm  600-800
     Grating g/mm  2400
     Slit-14 nm res.  0.20

     

加入
NIR3b

Wavelength Range (nm) : 800-1000

  •  Wavelength Range in nm  800-1000
     Grating g/mm  1800
     Slit-14 nm res.  0.20

     

加入
UV3

Wavelength Range (nm) : 200-300

  •  Wavelength Range in nm  200-300
     Grating g/mm  1800
     Slit-14 nm res.  0.10

     

加入
UV3b

Wavelength Range (nm) : 300-400

  •  Wavelength Range in nm  300-400
     Grating g/mm  1800
     Slit-14 nm res.  0.10

     

加入
VIS3

Wavelength Range (nm) : 400-500

  •  Wavelength Range in nm  400-500
     Grating g/mm  1800
     Slit-14 nm res.  0.10

     

加入
VIS3b

Wavelength Range (nm) : 500-600

  •  Wavelength Range in nm  500-600
     Grating g/mm  1800
     Slit-14 nm res.  0.10

     

加入
VIS3c

Wavelength Range (nm) : 600-700

  •  Wavelength Range in nm  600-700
     Grating g/mm  1800
     Slit-14 nm res.  0.10

     

加入
NIR3

Wavelength Range (nm) : 700-800

  •  Wavelength Range in nm  700-800
     Grating g/mm  1800
     Slit-14 nm res.  0.10

     

加入
NIR2

Wavelength Range (nm) : 800-925

  •  Wavelength Range in nm  800-925
     Grating g/mm  1200
     Slit-14 nm res.  0.10

     

加入
 Spectrometer channels  Expandable to 8
 Spectrometer ranges  190-1000nm wavelengths
 Optical resolution  HR=0.1nm or SR=0.2nm
 Detector type  2048 pixel CCD array
 Laser type  Pulsed Nd-YAG @1.06um
 Laser model & rep rate  Kigre MK-367, 1 Hertz
 Laser lifetime  > 300,000 shots
 SR wavelength range  200nm =200-400/400-600
 HR wavelength range  100nm =200-300/300-400
 Additional channel  SR or HR
 Case Dimensions  7 x 14 x 18 inches
 Data transfer speed  480 Mbits per second
 Power consumption  350 mA @ 12 VDC
 Computer Interface  USB-2 port
 Laser power  25 milli-joules (4ns pulse)
 Power to sample  6 MegaWatts
 Plasma chamber  2 x 2 x 3 inches
 Operating systems  Win98/Me/00/XP
 Software included  SpectraWiz Spectral-ID
 Customizable software  LabView,Excel+VBA,Delphi