Spec
BLACK-Comet UV-VIS Spectrometer
- Measurements in the 200-1080nm or 220-1100nm range
- Concave grating optics for high performance applications
- Super Range concave grating with dual blaze for best sensitivity
- Enhanced spectral imaging with no mirrors for lowest possible stray light
- Flat field imaging for uniform resolution
- No optical adjustments for extreme thermal stability
- TEC upgrade now available for 2016! Increases S/N by 60%
- Concave gratings white paper
Model | Description |
---|---|
BLK-C | .Wavelength Range (nm): 190-850 .Grating g/mm: 590 .Slit-200㎛, res.(nm): 6.0 .Slit-100㎛, res.(nm): 3.0 .Slit-50㎛, res.(nm): 1.5 .Slit-25㎛, res.(nm): 0.85 .Slit-14㎛, res.(nm): 0.75 |
BLK-CXR | .Wavelength Range (nm): 280-900 .Grating g/mm: 590 .Slit-200㎛, res.(nm): 6.0 .Slit-100㎛, res.(nm): 3.0 .Slit-50㎛, res.(nm): 1.5 .Slit-25㎛, res.(nm): 0.85 .Slit-14㎛, res.(nm): 0.75 |
Download |
---|
StellarNet-BLACK-Comet-SPEC.pdf |
BLACK-Comet-SR Spectrometer
- Measurements in the 190-850nm or 280-900nm ranges
- High performance concave grating optics for UV-VIS applications
- Superb spectral imaging with no mirrors for lowest possible stray light
- Enhanced UV Sensitivity & Flat-field imaging for uniform resolution
- No optical adjustments for extreme thermal stability and ruggedness
- Thermo-electrically Cooled Detector (TEC) upgrade increases S/N by 60%
- BLACK-Comet-SR (Super Range) for wide range applications 200-1100nm
- BLACK-Comet-HR (High Resolution) for high resolution applications <0.4nm
Model | Description |
---|---|
BLK-C-SR | .Wavelength Range (nm): 200-1080 .Grating g/mm: Dual Blaze Concave .Slit-200㎛, res.(nm): 8.0 .Slit-100㎛, res.(nm): 4.0 .Slit-50㎛, res.(nm): 2.0 .Slit-25㎛, res.(nm): 1.5 .Slit-14㎛, res.(nm): 1.3 |
BLK-CXR-SR | .Wavelength Range (nm): 220-1100 .Grating g/mm: Dual Blaze Concave .Slit-200㎛, res.(nm): 8.0 .Slit-100㎛, res.(nm): 4.0 .Slit-50㎛, res.(nm): 2.0 .Slit-25㎛, res.(nm): 1.5 .Slit-14㎛, res.(nm): 1.3 |
Download |
---|
StellarNet-BLACK-Comet-SPEC.pdf |
BLACK-Comet-HR Spectrometer
- Measurements in the 200-600nm or 380-750nm ranges
- Resolutions as low as 0.4nm with high performance concave grating optics
- Perfect spectral imaging with no mirrors for lowest possible stray light
- Flat field imaging for uniform resolution
- No optical adjustments for extreme thermal stability
Model | Description |
---|---|
BLK-C-HR-UV | .Wavelength Range (nm): 200-600 .Grating g/mm: 590 .Slit-14㎛, res.(nm): 0.40 |
BLK-C-HR-VIS | .Wavelength Range (nm): 380-750 .Grating g/mm: 590 .Slit-14㎛, res.(nm): 0.40 |
Download |
---|
StellarNet-BLACK-Comet-SPEC.pdf |